| PRODUCT CLASSIFICATION |
|
|
|
 |
|
| ※ Spoke Type Load Cells
|
| QH-61F | | Date: 2014-09-12 click :1118 |  | |
|
Rated load |
t |
1~5 |
10~20 |
|
Rated output |
mv/v |
2.0±0.01 |
2.8±0.01 |
|
Accuracy grade |
%FS |
±0.03 |
±0.05 |
±0.03 |
±0.05 |
±0.1 |
|
Linearity error |
%FS |
±0.03 |
±0.05 |
±0.03 |
±0.05 |
±0.1 |
|
Hysteresis error |
%FS |
±0.03 |
±0.05 |
±0.03 |
±0.05 |
±0.1 |
|
Repeatability error |
%FS |
±0.02 |
±0.03 |
±0.02 |
±0.03 |
±0.05 |
|
Creep error |
%FS/30min |
±0.03 |
±0.05 |
±0.03 |
±0.05 |
±0.05 |
|
Temperature coefficient of ZERO |
%FS/10℃ |
±0.02 |
±0.03 |
±0.05 |
|
Temperature coefficient of SPAN |
%FS/10℃ |
±0.02 |
±0.03 |
±0.05 |
|
Zero unbalance |
%FS |
±1 |
|
Safe overload |
%FS |
150 |
|
Output resistance |
Ω |
700±10 |
|
Input resistance |
Ω |
750±30 |
|
Insulation resistance |
MΩ |
5000(50VDC) |
|
Excitation voltage |
V |
10(DC) |
|
Maximum excitation |
V |
15(DC) |
|
Compensation temperature |
℃ |
-10~+40 |
|
Operating temperature |
℃ |
-10~+60 |
|
Protection |
/ |
IP67 |
|
Mode of connection
|
4-core 12 meters cable
Excitation+ red; Signal+ green ;
Excitation- black ;Signal- white. | |
|
|
|
|
|